About 63 results
Open links in new tab
  1. Twisting the wires with linesman pliers before using a wire nut ...

    Nov 9, 2020 · I usually pre twist most solid wire connections especially with more than two wires. Lately my favorite tool Is the Ideal screwdriver with the wire nut twister in the handle works good especially …

  2. Stranded Wire and Wire Nuts | Information by Electrical Professionals ...

    Nov 24, 2004 · Re: Stranded Wire and Wire Nuts I used to have trouble with the stranded fixture wire until I learned a couple of tricks. First, I would toss the wire connectors that came with the fixture and …

  3. Safety of twist on wire connectors aka "wire nuts"

    Jan 19, 2022 · Are wire nuts acceptable as insulation on a splice? I know it may be unlikely but if someone touches the splice with a wire nut, technically, you can still see copper inside the wire nut …

  4. Connecting Stranded to Solid Wire | Information by Electrical ...

    Feb 18, 2019 · What is the acceptable method to connect stranded copper wire to solid copper wire using a wire nut. In specific I am connecting an Aube thermostat to 10 ga romex for a 4KW heater.

  5. Do you twist your solid wires together before you put them in a …

    Mar 25, 2011 · And are you implying that twisting a wire around another makes it mechanically secure? I am saying twisting 2 or more solid conducters together with your linesmans will give you a …

  6. To pretwist or not | Information by Electrical Professionals for ...

    Oct 30, 2012 · The wire nut's ability to hold the wires together becomes academic- all you need is for the thing to stay in place. Are you failing to take advantage of the full potential of the wire nut?

  7. wire nuts underground pull box 480vac | Information by Electrical ...

    Jun 30, 2022 · Can someone point me to the NEC code that states it's OK to use "waterproof" wire nuts in an underground standard pull box with 480vac? Or point me to the code that states it's OK to use …

  8. NFPA 79 - wire nuts in motor connection boxes | Information by ...

    In NFPA 79-2007, Clause 13.5.9.2 states, "Electrical connections at motor terminal boxes shall be made with an identified method of connection. Twist-on wire connections shall not be used for this …

  9. Wire nut ampacity | Information by Electrical Professionals for ...

    Sep 23, 2022 · Is the ampacity of a wire nut determined by the maximum wire size it's designed for? Never really thought much of it until recently . I've gone on 2 service calls, one a j box connection …

  10. Wires under a wire nut | Information by Electrical Professionals for ...

    Mar 16, 2010 · I just recentlet failed an inspection because I had 5 #12 grounds under a red wire nut. I was told that I could only have four wires under 1 wire nut. where in the nec does it say this. I can not …